TENDERS FOR building commissioning

Following active tenders available for building commissioning across India. View building commissioning tender details and building commissioning tender notices (NIT) for free. Download Tender documents for building commissioning.


Filters


141 - 147 of 147 Tenders

gujarat
323 Crores
Expires on 03rd Oct, 2024
rajasthan
Not Specified.
Expires on 24th Sep, 2024
gujarat
9185 Crores
Expires on 14th Oct, 2024
west bengal
supply cost of items required for conversion of furnaces no. 6963-08 at rfs
2981 Crores
Expires on 27th Sep, 2024
maharashtra
Not Specified.
Expires on 01st Oct, 2024
maharashtra
Part 1 General Rules, Part II TA Rules, Part III Leave Rules, Part IV DA DR and HRA, CCS Pension Rules, CCS, Extraordinary Pension Rules, CGEGIS Insurance scheme, Medical attendance rules, CCS or CCA Rules, CCS Conduct, Rules, Leave travel concession rules, House Builiding, Advance Rules, Suspension and Reinstaement, CCS TEMP, Service Rules 1965, Seniority and promotion Central, Government, Reservation and concession for SCs and ST, and OBC mandal Commission, Reservation and concession, for persons bench mark Disability, Right to information Act, 2005, Manual Disciplinary proceedings, Manual of Office, Procedure With Notes and instructions, Master guide for FR, SR and service Rules, Standard specification and Code of, Practice for water Bound Macadam 3rd revision, Specifications for bituminous Macadam 1st revision, Code, of practice for road Markings, Guidelines for road markings, 2nd revision with CD, Guidelines for Design and, Construction of River Training and control works for Road, Bridge 2nd revision, Specifications for dense graded, Bituminous Mixes, Code of practice for concrete Road, Bridges 1st revision, Specifications for Readymade, bituminous pot hole parching Mix using Cut back Bitumen, Guidelines for Evaluation of Load carring capacity of bridge, 1st revision, Hill Road Manual, Guidelines for Load Testing, of Bridges 1st revision, Guidelines for use of interlocking, Concrete Block Pavement 1st revision, Guidelines for, retrofitting of steel Bridges by Pre stressing, Raod Tunnels 1st revision, Guidelines for design and, installation of Gabion Structure, Specifications for Road and, Bridge works 2013 5th revision, Tentative specification for, construction of stabilized soil roads with soft aggregates in, areas of moderate and high rain fall, Guidelines for design, and Horizontal curves for Highways and Design Tables 1st, revision, Highway Engg by Khanna and CEG Justo and A, veeraraghvan, Principle and practices in Highways Engg by, LR Kediyali, Principles of pavement design by EJ Yoder MW, Witczak, Traffic and Highway engineering by NJ Garbar and, LA Hoel, Highway Engineering hand book, A course in, Highway Engineering, Swamy Hand Book 2024, Building, Construction, Flow in open channel, Finite element analysis, Theory and application with ANSYS, Essential Engg, Design, of Bridge structure, Strength of Material, Inventory control, and Management, Engineering Mechanics, Dynamics of, Structures Applications to Earth Water Eng, The story of my, Experiments with truth, Strength of Materials, Harbour and, Dock and Tunnel Engg, For the love of India Life and Times, of Jamsedji Tata, Structural Analysis, Applied Mathematics, Applied Science, Applied Mechanics, Advance Surveying, Concrete Technology, Water, resources Engineering, Public health Engineering, Business Communication using computer, Physics CBSE, Class- 10 books, Chemistry CBSE Class- 10 books, Math, CBSE Class- 10 books, English Grammer CBSE Class- 10, books
manual of office procedure with notes and instructions
Not Specified.
Expires on 10th Oct, 2024
west bengal
Dismantling of Old U. s of Timer Panels including its, conenction and its accessories etc of any type complete all, as specified and directed., Dismantling Existing UG U. s, serviceable cable of any type of following sizes a. 10 Sqmm, 4 Core., As per serial No. 2 b. 16 Sqmm 4 Core., As per, serial No. 2 c. 25 Sqmm 4 Core., As per serial No. 2 d. 35, Sqmm 3. 5 Core., As per serial No. 2 e. 50 Sqmm 3. 5 Core., S and L testing and commissioning of cable XLPE Insulated, screened PVC bedded galvanized steel strip or wire power, cables aluminium conductor of following sizes. a. 10 Sqmm 4, Core., As per serial No. 7 b. 16 Sqmm 4 Core., As per serial, No. 7 c. 25 Sqmm 4 Core., As per serial No. 7 d. 35 Sqmm 3. 5, As per serial No. 7 e. 50 Sqmm 3. 5 Core., Relaying of, existing cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured electric power, cables heavy duty 1100V grade specified a. 10 Sqmm 4, As per serial No. 12 b. 16 Sqmm 4 Core., No. 12 c. 25 Sqmm 4 Core., As per serial No. 12 d. 35 Sqmm, 3. 5 Core., As per serial No. 12 e. 50 Sqmm 3. 5 Core., M and, L for Excavation in trenches upto 1. 5m deep Hard dense soil, M and L for Sand filling in trenches including watering and, consolidation, M and L for removing of surplus excavated, soil, M and L for Returning and filling of surplus excavated, Supply and laying common burnt clay building sub, class B old size bricks laid in right angle along the cable, complete all as specified., M and L for PCC demolition of, timer panel Solar lights etc of any type any description and, in any position, M and L for Straight through LT cable heat, shrinkable jointing kit suitable for LT UG of following sizes, cable a. 10 Sqmm 4 Core., b. 16 Sqmm 4 Core., c. 25, Sqmm 4 Core., d. 35 Sqmm 3. 5 Core., e. 50 Sqmm 3. 5, S and F automatic timer switch distribution board, made of 3. 15mm thick CRCA Sheet double door outdoor, type with epoxy powder coating of RAL7035, All as per, specification pdf Item No 12 and 12 a to c nd e to f but, Incomer MCCB shall be 4 pole MCCB 100A 01 Nos Ics 100, percent Icu 25 KA with electrocnic protection etc., Supply, and fixing all in one Hybrid LED Solar street light fitting 40, Watt 220V to 240VA 50Hz IP Rating 65 CCT etc, Dismantling of Old U. S Solar lights of any type including PCC, demolition complete all as specified and directed., M and L, for plain concrete cement 1. 3. 6 type C2 using 40mm graded, coarse aggregate for foundation of Solar lights Timer Panels, including necessary form work etc, M and L for earthing, complete with galvanized steel earth plate electrode 600 X, 600 X 6 mm thick buried directly in ground earth pit not less, than 2. 25 m etc, Heavy Duty Pipe Wrench as per IS 4003, Q3
m and l for excavation in trenches upto 1.5m deep hard dense soil
Not Specified.
Expires on 12th Oct, 2024