ASV- 8 DEA. PEGGING FROM AUX. STEAM HEADER, CRHV- 6, DEA. PEGGING FROM CRH LINE, CDV- 26 MAIN, CONDENSATE CONTROL, CDV- 23 LOW LOAD CONDENSATE, CONTROL, CDV- 39 GSC MIN. FLOW RECIRCULATION, CDV-, 43 EXCESS RETURN TO CST, CDV- 72 CONDENSATE FOR, VALVE GLAND SEALING, DRV- 2 AND DRV- 8 HPH- 8A AND 8B, NORMAL DRAIN TO HPH- 7A AND 7B, DRV- 5 AND DRV- 11, HPH- 8A AND 8B ALT. DRAIN TO FT- A, DRV- 15 AND DRV- 22, HPH- 7A AND 7B NORMAL DRAIN TO DEAERATOR, DRV- 18, AND DRV- 25 HPH- 7A AND 7B ALT. DRAIN TO FT- A, DRV- 31, LPH- 3 ALT. DRAIN TO FT- B, DRV- 48 DEAERATOR OVERFLOW, TO FT- B, DRV- 53 AND DRV- 59 HPH- 9A AND 9B NORMAL, DRAIN TO HPH- 8A AND 8B, DRV- 56 AND DRV- 62 HPH- 9A, AND 9B ALT. DRAIN TO FT- A, DRV- 65 LPH- 4 NORMAL DRAIN, TO LPH- 3, DRV- 82 LPH- 5 NORMAL DRAIN TO LPH- 4, DRV-, 68 LPH- 4 ALT. DRAIN TO FT- B, DRV- 85 LPH- 5 ALT. DRAIN, DMV- 43 DM NORMAL MU TO HOTWELL, DRV- 28, DRIP PUMP DISCHARGE CONTROL, ASV- 2 AUX. STEAM TO, BFPTs, CRHV- 2 CRH STEAM TO BFPTs, DMCW- 25 DMCW, SYSTEM FOR PLANT AUXs, 1 by 4 INCH SS TUBING- 12, METER FOR EACH TAG, SS FITTINGS for connection to Air, Filter Regulator- FOR EACH TAG, SS FITTINGS for, connection to Air Lock Relay- FOR EACH TAG, SS FITTINGS, for connection to IA Header Isolation Valve- FOR EACH TAG, SS EQUAL TEE- FOR EACH TAG, SS 1 by 2 INCH NPT- M X, 1 by 4 INCH OD TUBE CONNECTOR- FOR EACH TAG, COMMISIONING SPARES- Gaskets and Gland Packing, VALVE DIAGNOSTIC AND CONFIGURATION SOFTWARE, CV, TEST CHARGES, Pneumatic Diaphragm for Diaphragm, actuated valve or equivalent item applicable for selected, Actuator Type shall be provided- 2 nos. for each type of, Actuator, Actuator Seal Kit for Pneumatic Cylinder actuated, valve- 2 nos. for each type of Actuator, Gland Packing- 1, set for each type of Control Valve, Plug, Seat, Cage, Stem, etc.- 1 set for each type of Control Valve, Retainer Ring, Seal Ring etc.- 1 set for each type of Control Valve, Gasket,- 2 sets for each type of Control Valve, Control Valve or, Power Cylinder Positioner complete Set- Single Acting- 10, percent of total quantity used in the system or minimum 2, nos. whichever is more for each type and model., Control, Valve or Power Cylinder Positioner complete Set- Double, Acting- 10 percent of total quantity used in the system or, minimum 2 nos. whichever is more for each type and, model., Complete Set of Solenoid Valve for Pneumatic type, On Off Valve or Power Cylinder- 2 nos. for each type and, ratings, Position Limit Switch for Pneumatic type On Off, Valve or Power Cylinder- 10 nos. for each type and ratings, Air Lock Relay- 10 nos. for each type, Signal Air Booster, Unit- 2 nos. for each type
Noida, Uttar Pradesh, India
Important Dates
Bid submission started
Sept. 13, 2024, 8:37 p.m.
Bid submission ended
Sept. 23, 2024, 9:30 p.m.
Price Information
Price
Unknown
EMD
Unknown
Tender Description:
None
Tender Type:
open
Dates:
Published on
Sept. 13, 2024, 8:37 p.m.
Bid Opening Date
Sept. 23, 2024, 10 p.m.
Doc Download started
Unknown
Doc Download ended
Unknown
Documents
Sign up to access Documents
START A FREE 7-DAY TRIAL
Department & Other Tender Information
Sign up to access Tender Information
START A FREE 7-DAY TRIAL